Forum

Welcome to the Panbo Marine Technology Forums.

Etaoin Shrdlu
Etaoin Shrdlu
@etaoin
Active Member
Joined: October 12, 2021 9:13 am
Last seen: October 28, 2021 8:43 am
Topics: 1 / Replies: 5
Reply
RE: Reverse engineering Mastervolt Master Adjust protocol

The configuration options of the Mass Combi can be accessed with the commands 0x01 to 0x1B, which means there are 27 paramaters (or commands) in total...

2 years ago
Forum
Reply
RE: Reverse engineering Mastervolt Master Adjust protocol

Here's a teaser of the settings I've so far been able to identify:

2 years ago
Forum
Reply
RE: Reverse engineering Mastervolt Master Adjust protocol

@ben-stein Oh, many thanks - I took this on as a challenge during Covid lock-down when I had little else to do, and thought it would be wrong not to s...

2 years ago
Forum
Reply
RE: Reverse engineering Mastervolt Master Adjust protocol

Here is what I think I know about command 0x25, the response of which drives the remote control panel LEDs: Quit a few gaps as you can see, an...

2 years ago
Forum
Reply
RE: Reverse engineering Mastervolt Master Adjust protocol

The first hurdle I faced was figuring out what kind of serial interface the Mass Combi uses; in the product literature it is referred to as a "QRS232"...

2 years ago
Forum
Topic
Forum
Replies: 10
Views: 4953